EPU-100

“Electronıc Pıckup Unıt” for Asynchronous Generators

 

EPU stands for Electronic Pickup Unit (in association to MPU the Magnetic Pickup Unit).
The EPU-100 receives the electrical signal and converts it into a “MPU signal”. This information about the speed of rotation of the asynchchronous generator can be fed into a genset control (for example an easYgen). So the genset control can decide for connecting the asynchronous generator to the mains/utility. Woodward’s EPU-100 is particular suitable to work with the very small voltage (as low as 0.5 Vac and as high as 600 Vac) a asynchronous generator produces until it’s breaker is closed.

EPU-100 is a small plug and play device that requires no configuration or adjustments. In combination with Woodward’s easYgen genset controllers, it provides an ideal solution for asynchronous generator sets. The easYgen comes with a dedicated asynchronous firmware implemented by delivery and setup for MPU signal coming from EPU-100 is just a few parameter settings away.

This standard DIN rail mounted device contains an LED for easy diagnostics.
The wiring printing on the housing makes it very easy to install it. 

Features include:

  • Simple plug and play converter
  • Easy and convenient to install, operate, and diagnose
  • Seamless integration with Woodward genset controls
  • CE marked

 

 

Specifications

 Attribute

  Unit   Value  Remarks

 Input

Remanence voltage input

 VAC  0.5 .. 600   L1 – L2

Input impedance

 kΩ   > 240

Input frequency range

 Hz  16 .. 85

 Output

Output frequency range

  Hz  128 .. 680   8 times higher than input frequency

Accuracy

  % 5   For 40 .. 60 Hz

“MPU output” Signal

  VDC   4.5 .. 5.5

Reaction time

  ms   < 400   Tracking time

LED frequency

  Hz   ~ 4 .. 21   4 times lower than input frequency

 Installation

Supply voltage

  VDC  8 .. 42V   Vnom = 24V

Supply current

  ADC   < 0.02

Wire size “inflexible”

  mm2   0.2 .. 4

Wire size “flexible”

  mm2   0.2 .. 2.5

Cable length to genset control

  m   < 10   shielded

Cable length to power supply

  m  < 30   

Power line to the “mains breaker”

  shielded

 Environment

Absolute altitude for operation

  m  .. 4000

Ambient operation temperature

 °C  -40 .. +70

Storage temperature

 °C   -40 .. +100

Dimensions

mm   30 x 75 x 55   W x D x H

Standards, approvals, approbations

DIN EN 61010-1, CE
(UL on request)

 CAT II 300-600 V acc.
to DIN EN 61010-1
Approvals
epu100